Chapter 2: Commissioning procedures 13
2.3 Seatrial calibration
WARNING: Ensure you have sufficient sea room for calibration. The seatrial
calibration manoeuvres require a clear, familiar area of water. Ensure you
are not likely to collide with any vessel or other obstruction during
calibration.
WARNING: Maintain sensible speeds. The autopilot may make unexpected
turns.
CAUTION: Sailing vessels should perform the sea trial under engine power.
When the dockside setup and calibration procedures are complete, navigate to a
place where you have plenty of sea room, then carry out the seatrial calibration
procedures to complete the SmartPilot X system commissioning.
Note: You may exit the calibration process at any time by pressing
CANCEL
on your ST70 con-
troller. The next time you power up, you will be prompted to complete calibration.
Begin Seatrial calibration
1. Press
ENTER
to begin seatrial calibration.
2.) Press
ENTER
for standby warning message.
3.) Press
ENTER
to begin compass calibration.
Press ENTER to continue.
Sea Trial Calibration
D10903-1
Before you can use your
autopilot you need to do
some open water checks.
The water must be calm
with light wind.
Leave plenty of room
to manouevre.
Press CANCEL to exit
without saving.
Press ENTER to continue.
Sea Trial Calibration
D10904-1
STANDBY
IMPORTANT!
You can press
STANDBY at any time
to take over the helm.