ST60 Multi
Instrument
Owner’s
Handbook
Document number: 81039-4
Date: 1 April 2004
81039_4.book Page i Wednesday, March 24, 2004 3:14 PM
Przeglądanie stron 0
1 2 3 4 5 6 ... 53 54

Podsumowanie treści

Strona 1 - Handbook

ST60 Multi InstrumentOwner’s HandbookDocument number: 81039-4Date: 1 April 200481039_4.book Page i Wednesday, March 24, 2004 3:14 PM

Strona 2

viii ST60 Multi Instrument Owner’s HandbookRemote controlWhen connected to SeaTalk, the ST60 Multi instrument can be controlled remotely by a SeaTalk

Strona 3 - Important information

Preface ixD4440-3ST60 MultiInstrumentOwner'sHandbook147323256MULTIOperationChapter selection and contentKey:881039_4.book Page ix Wednesday, Mar

Strona 4

x ST60 Multi Instrument Owner’s Handbook81039_4.book Page x Wednesday, March 24, 2004 3:14 PM

Strona 5 - Contents

Chapter 1: Operation 1Chapter 1: Operation1.1 IntroductionThis handbook describes how to operate, maintain and install the Raymarine ST60 Multi instru

Strona 6

2 ST60 Multi Instrument Owner’s HandbookChapter selection and contentChapter namePages within chapter Listed in sequence.Accessed with key.Ke

Strona 7

Chapter 1: Operation 3To display a particular page:1. Refer to the Chapter selection and content diagram to determine the location of the information

Strona 8

4 ST60 Multi Instrument Owner’s Handbook1.3 Chapters and pagesThis section lists all the available pages along with titles and salient points.Depth ch

Strona 9 - Data inputs

Chapter 1: Operation 5Wind chapter pagesHeading chapter pagesFunction Title RemarksApparent wind speedAPP Either knots (KTS) or meters per second (M/S

Strona 10 - Parts supplied

6 ST60 Multi Instrument Owner’s HandbookNavigate chapter pagesEnvironment chapter pagesFunction Title RemarksBearing to way-pointBTW Displayed in degr

Strona 11 - Preface ix

Chapter 1: Operation 7Autopilot chapter pages1.4 Using the track keyIf your system includes a SeaTalk autopilot working in conjunction with a track pl

Strona 12

Raymarine, ST60 and SeaTalk are trademarks of Raymarine Limited© Handbook contents copyright Raymarine Limited 200481039_4.book Page ii Wednesday, Mar

Strona 13 - Chapter 1: Operation

8 ST60 Multi Instrument Owner’s HandbookNote: If a depth alarm occurs while a page in the depth chapter is displayed, or a wind alarm occurs while a

Strona 14 - Chapter selection and content

Chapter 1: Operation 9NMEA to SeaTalkThe ST60 Multi instrument decodes certain data from NMEA when available, and if the respective data is not alread

Strona 15 - Chapter 4, Calibration

10 ST60 Multi Instrument Owner’s HandbookContrastTo adjust the display contrast:1. Hold down the key for approximately two seconds, to enter the cont

Strona 16 - 1.3 Chapters and pages

Chapter 2: Maintenance & Troubleshooting 11Chapter 2: Maintenance & Troubleshooting2.1 MaintenanceServicing and safety• Raymarine equipment sh

Strona 17 - Heading chapter pages

12 ST60 Multi Instrument Owner’s HandbookCablingExamine all cables for chafing or other damage to the outer shield and, where necessary, replace and r

Strona 18 - Environment chapter pages

Chapter 2: Maintenance & Troubleshooting 13Technical supportRaymarine provides a comprehensive customer support service, on the world wide web and

Strona 19 - 1.5 Alarms

14 ST60 Multi Instrument Owner’s Handbook81039_4.book Page 14 Wednesday, March 24, 2004 3:14 PM

Strona 20 - 1.6 Operating with NMEA

Chapter 3: Installation 15Chapter 3: InstallationThis chapter describes how to install the ST60 Multi instrument, and when supplied, the Auxiliary Ala

Strona 21 - 1.7 Display settings

16 ST60 Multi Instrument Owner’s HandbookCAUTION: The presence of moisture at the rear of the instrument could cause damage either by entering the in

Strona 22 - 1.9 Remote control

Chapter 3: Installation 17age the equipment, but may cause the loss of some information and may change the operating mode.• Raymarine specified cables

Strona 23 - 2.1 Maintenance

Preface iPrefaceImportant informationSafety noticesWARNING: Product installation & operationThis equipment must be installed and operated in ac

Strona 24 - 2.2 Troubleshooting

18 ST60 Multi Instrument Owner’s HandbookEach ST60 instrument is supplied with a standard bezel for surface mounting. Optional mounting kits are avail

Strona 25 - Technical support

Chapter 3: Installation 192. Apply the surface mount template (supplied at the rear of this handbook) to the selected location and mark the centers fo

Strona 26

20 ST60 Multi Instrument Owner’s Handbook4. Snap the low-profile bezel (8) in position over the instrument, so that the rub-ber keys are correctly loc

Strona 27 - Chapter 3: Installation

Chapter 3: Installation 21• There is sufficient space behind the selected location to accommodate the rear of the instrument and connectors.3. Apply t

Strona 28 - EMC installation guidelines

22 ST60 Multi Instrument Owner’s Handbookit is only suitable for use in positions where the instrument will not be exposed to water.To bracket mount y

Strona 29 - 3.2 Procedures

Chapter 3: Installation 23the cable will depend on the locations of the Auxiliary Alarm and instrument, but however you run the cable, observe the fol

Strona 30 - Fitting the instrument

24 ST60 Multi Instrument Owner’s HandbookUse crimped spade terminals to connect to the NMEA connectors. In order to ensure a secure connection when fi

Strona 31 - Flush mounting

Chapter 3: Installation 25Power supply connectionsCAUTION: When instruments are connected to SeaTalk, ensure that the power supply for the SeaTalk 12

Strona 32

26 ST60 Multi Instrument Owner’s Handbook81039_4.book Page 26 Wednesday, March 24, 2004 3:14 PM

Strona 33 - Bracket mounting

Chapter 4: Calibration 27Chapter 4: Calibration4.1 IntroductionThe ST60 Multi instrument is set up with factory-programmed default settings, so in ord

Strona 34 - Auxiliary alarm option

ii ST60 Multi Instrument Owner’s Handbook81039_4.book Page ii Wednesday, March 24, 2004 3:14 PM

Strona 35 - Connecting the instrument

28 ST60 Multi Instrument Owner’s HandbookProcedureTo carry out a User calibration:1. Power up the ST60 Multi instrument.2. Press the and keys for

Strona 36

Chapter 4: Calibration 29eitherfrom sheet 2to sheet 2Useto set the required valueson each screenUser calibration - sheet 1D4406_1chaptrackChaptertitle

Strona 37 - Power supply connections

30 ST60 Multi Instrument Owner’s HandbookTime offsetYou can apply an offset from -12 hours to +12 hours in 1 hour increments, to set your system time

Strona 38

Chapter 4: Calibration 31Units setupYou can use the Units Setup screen to set:• Temperature (TEMP) units to either °C or °F.• Speed (SPD) units to eit

Strona 39 - Chapter 4: Calibration

32 ST60 Multi Instrument Owner’s HandbookPop-up pilotSwitches the pop-up pilot function on and off.Instrument configurationYou can streamline the oper

Strona 40 - Procedure

Chapter 4: Calibration 33DPTH MAX Maximum Depth DepthSPEED Boat Speed SpeedSPD MAX Maximum Speed SpeedSPD AVG Average Speed SpeedSPD SOG SOG SpeedSPD

Strona 41 - Chapter 4: Calibration 29

34 ST60 Multi Instrument Owner’s HandbookLeaving User calibrationHold down the and keys for 2 seconds, to save your settings, exit User calibration an

Strona 42 - Time offset

Chapter 4: Calibration 354.4 Dealer calibrationThe Dealer calibration procedures enable the following parameters to be set:• User calibration on/off.

Strona 43 - Auxiliary alarm enable

36 ST60 Multi Instrument Owner’s HandbookVMG Velocity made goodCOG/SOG Course over ground and speed over groundTitle Response functionResponseD4410-1a

Strona 44 - Instrument configuration

Chapter 4: Calibration 37Factory defaultsYou can use this screen to reset the operating parameters to the factory default values. Use the track and re

Strona 45 - Chapter 4: Calibration 33

Preface iiiContentsPreface ...iImp

Strona 46 - 4.3 Intermediate calibration

38 ST60 Multi Instrument Owner’s Handbook81039_4.book Page 38 Wednesday, March 24, 2004 3:14 PM

Strona 47 - 4.4 Dealer calibration

D4436-1Machine hole90mm (3.54in)diameterDrill 5mm (3/16in) diameterDrill 5mm (3/16in) diameterShaded areas to be removedTOPST60 Surface Mount Template

Strona 48 - Dealer calibration

81039_4.book Page 40 Wednesday, March 24, 2004 3:14 PM

Strona 49 - Leaving Dealer calibration

Shaded area to be removedTOP109 mmST60 Flush Mount Template114 mm4 holes6 mm diameterD4437-181039_4.book Page 41 Wednesday, March 24, 2004 3:14 PM

Strona 50

81039_4.book Page 42 Wednesday, March 24, 2004 3:14 PM

Strona 51 - ST60 Surface Mount Template

iv ST60 Multi Instrument Owner’s HandbookChapter 2: Maintenance & Troubleshooting ...112.1 Mainten

Strona 52

Preface vDate format ... 28Time format ...

Strona 53 - Shaded area to be removed

vi ST60 Multi Instrument Owner’s Handbook81039_4.book Page vi Wednesday, March 24, 2004 3:14 PM

Strona 54

Preface viiIntroductionThank you for purchasing a Raymarine product. We are sure your ST60 instrument will give you many years of trouble-free operat