Strona 1 - Date: 1st April 1999

ST60 Wind &Close HauledWindInstrumentsOwner’sHandbookDocument number: 81105-3Date: 1st April 1999105_3cov.p65 06/04/01, 10:461

Strona 2 - 105_3cov.p65 06/04/01, 10:462

viii ST60 Wind and Close Hauled Wind Instrument Owner’s HandbookParts suppliedUnpack your ST60 instrument and check that the following items arepresen

Strona 3 - Contents

Introduction ixWorldwideDistributorsD4442-2ST60 WindInstrumentOwner'sHandbook1a 1b48932325b6These items are not with ST60 Close Hauled Wind711105

Strona 4 - 105_3int.p65 06/04/01, 10:462

x ST60 Wind and Close Hauled Wind Instrument Owner’s Handbook105_3int.p65 06/04/01, 10:4710

Strona 5 - Introduction iii

Chapter 1: Operation1Chapter 1: Operation1.1 Getting startedThis handbook describes how to operate, maintain and install theRaymarine ST60 Wind instru

Strona 6 - 105_3int.p65 06/04/01, 10:464

2ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookDigital displayThe digital display shows the following wind and speed information:• True/

Strona 7 - Introduction

Chapter 1: Operation3The flow charts show the sequence of key presses and displays for thevarious operating tasks. All key presses called for in the f

Strona 8 - Data inputs

4ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookTrue/ApparentPress the true/app. key to toggle between true and apparentinstrument readin

Strona 9 - Mounting options

Chapter 1: Operation5Setting alarm conditionsThe alarm threshold screens are accessed with the disp key (see theUsing the disp key flow chart), and en

Strona 10 - Parts supplied

6ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook1.3 Display illuminationWhen the instrument is first powered up, the display illumination

Strona 11 - Introduction ix

Chapter 2: Maintenance and Fault Finding 7Chapter 2: Maintenance and Fault Finding2.1 MaintenanceServicing and safety• Raymarine equipment should be s

Strona 12

© Copyright Raymarine Limited 2001105_3cov.p65 06/04/01, 10:462

Strona 13 - Chapter 1: Operation

8 ST60 Wind and ST60 Close Hauled Wind Instrument Owner’s Handbook2.2 Fault findingPrPrPrPrPreliminary preliminary preliminary preliminary preliminary

Strona 14 - 1.2 Normal operation

Chapter 3: Installation9Chapter 3: InstallationThis chapter describes how to install the ST60 Wind and ST60 CloseHauled Wind instruments, and associat

Strona 15 - Using the disp key

10ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookInstrumentInstrumentInstrumentInstrumentInstrument110mm (4.33in) 24mm(0.95in) 15mm(0.6in

Strona 16 - True/Apparent

Chapter 3: Installation11EMC guidelinesAll Raymarine equipment and accessories are designed to the bestindustry standards for use in the leisure marin

Strona 17 - Setting alarm conditions

12ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookConnections to other equipmentIf your Raymarine equipment is going to be connected to ot

Strona 18 - 1.4 Remote control

Chapter 3: Installation13The ST60 instruments can also be mounted behind a panel with justthe instrument dial and keys visible.Surface mountingTo surf

Strona 19 - 2.1 Maintenance

14ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookFlush mountingThe Flush Mounting Kit uses a low-profile bezel to reduce the fittedprofil

Strona 20 - 2.2 Fault finding

Chapter 3: Installation15D4356-2789Fitting the low profile bezelFlush mounting procedureFlush mount your instrument ( see the Flush mounting illustrat

Strona 21 - Chapter 3: Installation

16ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook D4307-3Flush mounting11345566. Screw the two fixing studs (1) into

Strona 22 - CAUTION:

Chapter 3: Installation17Note: An ST60 Close Hauled Wind instrument can only be used as arepeater instrument so a directly-connected transducer is not

Strona 23 - EMC guidelines

Introduction iContentsIntroduction... vEMC conformance ...

Strona 24 - 3.2 Procedure

18ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookRotavectaThe Rotavecta can be clamped to a 23 mm or a 25 mm rail by means ofan integral

Strona 25 - Surface mounting

Chapter 3: Installation19• If the cable has to be fed through the deck, always use a proprietarydeck gland.• Where cables are fed through holes, alway

Strona 26 - Flush mounting

20ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook4. Connect each wire at one end of the remaining cable to the same-coloured wire inside

Strona 27

Chapter 3: Installation21A range of Raymarine SeaTalk extension cables is available to connectseparated instruments. These cables are supplied with a

Strona 28 - Fitting transducers

22ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookPower supply connectionsSeaTalk systemsCAUTIONWhen instruments are connected to SeaTalk,

Strona 29 - Typical windvane installation

Chapter 3: Installation23 To fit a power cable:1. Run the cable from the instrument to a suitable 12 V dc powersource.Power connections for stand-alon

Strona 30 - Running transducer cable

24ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook105_3c03.p65 06/04/01, 10:4724

Strona 31 - Preparing wire for connection

Chapter 4: Calibration 25Chapter 4: Calibration4.1 IntroductionThe ST60 Wind instruments are set up with factory-programmeddefault settings, so in ord

Strona 32 - Connecting the instruments

26ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook3. Hold down the disp and true/app keys for approximately2 seconds to enter User calibra

Strona 33 - Signal connections

Chapter 4: Calibration 274.3 Intermediate calibrationThe intermediate calibration screens enable you to check:• The instrument software version number

Strona 34 - Power supply connections

ii ST60 Wind and Close Hauled Wind Instrument Owner’s HandbookChapter 2: Maintenance and Fault Finding ... 72.1 Maintenance ...

Strona 35

28ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookDealer calibration also gives access to the Factory defaults screen. Thisenables you to

Strona 36

Chapter 4: Calibration 29TRUEAPPHold down and for approximately 12 secondsdisptrueappDealer calibration - sheet 1Entry screenTRUEAPPTRUEAPPTRUEAPPvmgt

Strona 37 - Chapter 4: Calibration

30ST60 Wind and Close Hauled Wind Instruments Owner’s Handbookanddisptrueappto either apply factory defaultsor retain current settings(F1 = factory de

Strona 38 - Leaving User calibration

Chapter 4: Calibration 31Boat show mode (bSO)CAUTION:Do NOT enable this mode. It must only be used for demonstrationpurposes.Ensure that the Boatshow

Strona 39 - 4.4 Dealer calibration

32ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook105_3c04.p65 06/04/01, 10:4732

Strona 40 - Wind speed

D4436-1Machine hole90mm (3.54in)diameterDrill 5mm (3/16in) diameterDrill 5mm (3/16in) diameterShaded areas to be removedTOPST60 Surface Mount Template

Strona 41 - Chapter 4: Calibration 29

105_3tem.p65 06/04/01, 10:4734

Strona 42 - Dealer calibration - sheet 2

Shaded area to be removedTOP109 mmST60 Flush Mount Template114 mm4 holes6 mm diameterD4437-1105_3tem.p65 06/04/01, 10:4735

Strona 43 - Leaving Dealer calibration

105_3tem.p65 06/04/01, 10:4736

Strona 44

Document number: 84064-8April 2001Limited Warranty CertificateRaymarine warrants each new Light Marine/Dealer Distributor Product to be of good materi

Strona 45 - ST60 Surface Mount Template

Introduction iiiRunning transducer cable ... 18General ... 18

Strona 46

Factory Service CentersUnited States of America UK, Europe, Middle East, Far EastRaymarine Inc22 Cotton Road, Unit DNashua, NH 03063-4219

Strona 47 - ST60 Flush Mount Template

iv ST60 Wind and Close Hauled Wind Instrument Owner’s Handbook105_3int.p65 06/04/01, 10:464

Strona 48

Introduction vIntroductionThank you for purchasing a Raymarine product. We are sure yourST60 instrument will give you many years of trouble-free opera

Strona 49 - Limited Warranty Certificate

vi ST60 Wind and Close Hauled Wind Instrument Owner’s HandbookEMC conformanceAll Raymarine equipment and accessories are designed to the bestindustry

Strona 50 - Factory Service Centers

Introduction viiStand alone operationIn Stand alone operation, the ST60 Wind instrument is connected onlyto the relevant transducer and does not displ