Podsumowanie treści

Strona 1

Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine. The names Raytheon and RTN are owned by the Ra

Strona 2 - Installation

Chapter 1: Control Head Installation7Chapter 1: Control Head InstallationTMBIDATAD682110mm (4.33in)42mm (1.65in)24mm (1.00in)56mm (2.20in)88mm (3.46in

Strona 3 - P03 5TD, England

8ST30 Bidata Operation and Installation Handbook1.2 Mounting procedureD682a2413 561 Instrument 2 Fixing studs 3 Thumb nuts 4 Sealing gasket5 Depth

Strona 4 - Copyright Nautech 1992

Chapter 1: Control Head Installation91.3 Power supply (Stand-alone operation)Caution: The ST30 Bidata must be connected to a 12V supply only.–+++++SEA

Strona 5 - Package Contents

10ST30 Bidata Operation and Installation Handbook1.5 Connection to adjacent ST30 InstrumentsThe ST30 Bidata is supplied with a daisy-chain cable that

Strona 6 - Operation

Chapter 2: Transducer Installation11Chapter 2: Transducer Installation2.1 Connection to instrumentThe depth and speed transducers are supplied with 10

Strona 7 - Contents (cont.)

12ST30 Bidata Operation and Installation HandbookDepthSpeedSpeed and depthCaution: Plastic through hull transducers must not be used on vesselswith wo

Strona 8 - Introduction

Chapter 2: Transducer Installation132.3 Paddlewheel replacementIf the high speed paddlewheel (supplied) is to be fitted, or the existingpaddlewheel to

Strona 9

14ST30 Bidata Operation and Installation Handbook2.4 InstallationThe depth and speed transducers are supplied with detailed installationand maintenanc

Strona 10 - 1.1 Siting

Chapter 2: Transducer Installation15Siting of depth transducer (Standard through hull)The depth transducer must be vertical to within 10°, forward, af

Strona 11 - 1.2 Mounting procedure

16ST30 Bidata Operation and Installation HandbookIf any of the following transducers are to be used;• Bronze through hull depth (Z118)• In hull puck

Strona 12 - Extension Cable

TOP EDGE BLEEDMASK FOR2 COLOURSEATALKLOGOBIDATAOperation andInstallationST 30

Strona 13

Chapter 2: Transducer Installation17Transducer type Colour coding (cable tounit)Bronze through hulltriducer (Z093)Brown & white Ð cut backRed Ð re

Strona 14 - 2.2 Transducer type

18ST30 Bidata Operation and Installation HandbookChapter 3: Fault FindingAll Autohelm products are, prior to packing and shipping, subject tocomprehen

Strona 15 - Speed and depth

Chapter 3: Fault Finding19Note: After installation, poor performance may be experienced if thesurface of the depth transducer has not been 'wette

Strona 16 - 2.3 Paddlewheel replacement

20ST30 Bidata Operation and Installation HandbookChapter 4: Maintenance4.1 InstrumentAtmospheric conditions may cause condensation to appear on theins

Strona 17 - 2.4 Installation

Chapter 5: Operation21Chapter 5: OperationThe ST30 Bidata is set in the factory to:• display depth in feet• display speed in knots• operate with the

Strona 18 - 2.5 Cabling

22ST30 Bidata Operation and Installation Handbook• Deep alarmKnotsMetresDEPTHSPEEDD710Deep• Minimum depthKnotsMetresDEPTHSPEEDD710 Min• Offs

Strona 19

Chapter 5: Operation23• LogNmMetresDEPTHSPEEDD710Log• Maximum SpeedKnotsMetresDEPTHSPEEDD710Maximum• Average SpeedKnotsMetresDEPTHSPEEDD710AverageA

Strona 20

24ST30 Bidata Operation and Installation Handbook5.3 Light KeyCycles the level of instrument illumination. There are 3 levels withlevel 3 the brightes

Strona 21 - Chapter 3: Fault Finding

Chapter 6: Calibration25Chapter 6: Calibration6.1 Depth calibrationThe ST30 Bidata can be programmed to display depth information in feetor metres, se

Strona 22

26ST30 Bidata Operation and Installation HandbookUnits selection – depth1. Cycle Depth until the display shows feet or metres.TMD686BIDATADEPTH SPEED

Strona 23 - Chapter 4: Maintenance

TOP EDGE BLEEDMASK FOR2 COLOURSEATALKLOGONautech Limited, Anchorage Park, PortsmouthP03 5TD, EnglandTelephone (0705) 693611. Fax (0705) 694642

Strona 24 - Chapter 5: Operation

Chapter 6: Calibration272. Press Reset or to set the required depth.TMD688aBIDATADEPTH SPEED RESETMetresShallowDEPTHSPEED3. The Shallow Alarm is enabl

Strona 25 - 5.2 Speed Key

28ST30 Bidata Operation and Installation Handbook2. Press Reset or to set the required depth.TMD690aBIDATADEPTH SPEED RESETMetresDeepDEPTHSPEED3. The

Strona 26

Chapter 6: Calibration29OffsetThe instrument measures the water depth below the transducer. Todisplay water depth below the keel or to the surface an

Strona 27 - 5.4 Alarms

30ST30 Bidata Operation and Installation Handbook1. Press Depth until 'Offset' is selected.TMD693BIDATADEPTH SPEED RESETMetres Offset

Strona 28 - Chapter 6: Calibration

Chapter 6: Calibration316.2 Speed calibrationThe ST30 Bidata can be set to display speed in knots or mph and trip andtotal distance in nm or miles. Th

Strona 29 - Shallow alarm

32ST30 Bidata Operation and Installation HandbookUnits selection – log1. Cycle Speed until the display shows nm or miles.TMD697BIDATADEPTH SPEED RESET

Strona 30 - Deep alarm

Chapter 6: Calibration33Log calibrationThe ST30 Bidata should not be used for navigational purposes until thetransducer paddlewheel has been calibrate

Strona 31 - DEPTH SPEED RESET

34ST30 Bidata Operation and Installation HandbookEnter correction factor (CF)1. Press and hold and Depth. After 2 seconds the display willshow CAL.TMD

Strona 32

Chapter 6: Calibration354. To exit calibration and return to 'Speed and Depth' mode, press andholdand Depth for 2 seconds.TMD703BIDATADEPTH

Strona 33 - Exit depth calibration

36ST30 Bidata Operation and Installation Handbook2. Press Speed and Reset momentarilyTMD707BIDATADEPTH SPEED RESETDEPTHSPEED3. Calibration Lock/Unlock

Strona 34 - 6.2 Speed calibration

ST30 Bidata Operation and Installation HandbookDISPLAYBIDATADEPTHSPEEDFeetKnotsSPEEDRESETTMD681Autohelm and SeaTalk are registered Trade Marks of Naut

Strona 35 - Exit calibration

Chapter 6: Calibration376.4 Master/Repeater modeAs it leaves the factory, the ST30 Bidata is set to operate in master mode.In this mode the instrument

Strona 36 - Log calibration

38ST30 Bidata Operation and Installation Handbook3. Press Reset to change between modesTMD705A BIDATADEPTH SPEED RESETDEPTHSPEED4. To exit calibration

Strona 37 - Enter correction factor (CF)

Chapter 7: Specification39Chapter 7: SpecificationDetailed Specification:Power Consumption: 60mA (normal)100mA (illuminated)Depth transmitted power: 5

Strona 38 - 6.3 Calibration Lock/Unlock

40ST30 Bidata Operation and Installation HandbookSpeed:Boat speed: 0 to 99.9 knots or mph (0.1 increments)Trip distance: 0 to 999nm or miles (0.01 inc

Strona 39

TOP EDGE BLEEDMASK FOR2 COLOURSEATALKLOGONautech Limited, Anchorage Park, PortsmouthP03 5TD, EnglandTelephone (0705) 693611. Fax (0705) 694642

Strona 40 - 6.4 Master/Repeater mode

TOP EDGE BLEEDMASK FOR2 COLOURSEATALKLOGONautech Limited, Anchorage Park, PortsmouthP03 5TD, EnglandTelephone (0705) 693611. Fax (0705) 694642

Strona 41

ST30 Bidata Operation and Installation HandbookPackage ContentsThe following items are included in the ST30 Bidata package:1. ST30 Bidata instrument2.

Strona 42 - Chapter 7: Specification

3ST30 Bidata Operation and Installation HandbookOperationContentsIntroduction ...5

Strona 43

4ST30 Bidata Operation and Installation HandbookContents (cont.)6.2 Speed calibration... 31Unit

Strona 44

5ST30 Bidata Operation and Installation HandbookIntroductionDesigned for above or below deck installation, the ST30 Bidata can beused as a stand-alone

Strona 45

6ST30 Bidata Operation and Installation Handbook